Smartphone, Laptop Prove Reliable and Accurate for Acute Ischemic Stroke Decision

Mobile devices proved both reliable and accurate for the clinical decision to administer IV thrombolysis in patients with acute stroke, according to an ahead-of-print article in the April issue of the American Journal of Roentgenology (AJR).

To assess reliability and accuracy of IV thrombolysis recommendations made after interpretation of head CT images of patients with acute stroke symptoms displayed on smartphone or laptop reading systems - compared with those made after interpretation of images displayed on a medical workstation monitor - Antonio J. Salazar at the University of Los Andes in Bogotá, Columbia utilized a factorial design with 188 patients, four radiologists, and three reading systems to produce 2256 interpretations.

To evaluate reliability, Salazar and colleagues calculated the intraobserver and interobserver agreements using the intraclass correlation coefficient (ICC) and five interpretation variables: hemorrhagic lesions, intraaxial neoplasm, stroke dating (acute, subacute, chronic), hyperdense arteries, and infarct size assessment. Accuracy equivalence tests were also performed for the IV thrombolysis recommendation; for this variable, sensitivity, specificity, and ROC curves were evaluated.

Good or very good intraobserver agreements were observed for all the variables. Specifically, for those variables required to establish contraindications for IV thrombolysis, the agreements were ranked as very good. "This finding is important," wrote Salazar et al., "because it reflects the good performance of mobile devices to evaluate the most significant imaging variables for clinical decisions."

For IV thrombolysis recommendation, the main subject of this evaluation, the interobserver agreements for the three reading systems were ranked as very good (ICC > 0.88). Similarly, very good intraobserver agreements were observed for all comparisons (ICC > 0.84). The AUC values (0.83-0.84) and sensitivities (0.94-0.95) for IV thrombolysis recommendation were equivalent among all the reading systems at a 5% equivalent threshold.

A unique assessment of imaging-based recommendations for the administration of IV recombinant tissue plasminogen activator based on unenhanced brain CT scans, Salazar also noted: "These results constitute a strong foundation for the development of mobile-based telestroke services because they increase neuroradiologist availability and the possibility of using reperfusion therapies in resource-limited countries."

Antonio J Salazar, Nicolás Useche, Sonia Bermúdez, Aníbal J Morillo, Oscar Tórres, Manuel F Granja, Natalia Rueda, Brenda Ropero.
Accuracy and Reliability of the Recommendation for IV Thrombolysis in Acute Ischemic Stroke Based on Interpretation of Head CT on a Smartphone or a Laptop
American Journal of Roentgenology, 2020. doi: 10.2214/AJR.19.21896.

Most Popular Now

Researchers Capture First Images of Oxyg…

Oxygen in cancer tumors is known to be a major factor that helps radiation therapy be successful. Hypoxia, or starvation of oxygen, in solid tumors is also thought to be...

A New Method of Artificial Intelligence …

Despite the immense progress in the field of AI in recent years, we are still very far from human intelligence. Indeed, if current AI techniques allow to train computer agents...

PatchAi Startup has Arrived in the Marke…

PatchAi - a startup that offers, thanks to Artificial Intelligence and Machine Learning, an empathic virtual assistant to patients participating in clinical trials - announced that it has closed two...

FDA Authorizes Marketing of First Cardia…

Today, the U.S. Food and Drug Administration authorized marketing of software to assist medical professionals in the acquisition of cardiac ultrasound, or echocardiography, images. The software, called Caption Guidance, is...

Digital Health App Medicus AI Earns CE C…

Medicus AI, the Vienna-based health tech company, has received a ​Class I Medical Device CE Mark for its mobile application. The CE certification mark confirms that Medicus AI conforms to...

Portable Lab You Plug into Your Phone ca…

Engineers with the University of Cincinnati have created a tiny portable lab that plugs into your phone, connecting it automatically to a doctor's office through a custom app UC developed...

Helping Patients with Binge Eating Disor…

Behavioral therapy assisted by a smartphone app, delivered via telemedicine by a health coach, was an effective treatment for several symptoms of binge eating disorders, according to a study conducted...

SCCE's 8th Annual ECEI - European Compli…

16 - 18 March 2019, Amsterdam, The Netherlands. The European Compliance & Ethics Institute is the place to discuss compliance challenges and strategies with your peers from healthcare and across industry...

InterSystems Releases Novel Coronavirus …

InterSystems is releasing global functionality for its TrakCare® unified healthcare information system to screen and support patients with 2019-nCoV, the novel coronavirus infection that originated in Wuhan in China.

Telehealth Interventions Associated with…

Telehealth interventions are associated with improved obstetric outcomes, according to a review published from physician-researchers at the George Washington University. The article, published in the journal Obstetrics and Gynecology, presents...

CompuGroup Medical to Acquire Certain Ce…

CompuGroup Medical SE (CGM) and Cerner Corporation (NASDAQ: CERN), a global health care technology company, have entered into an agreement regarding the acquisition by CompuGroup Medical of a part of...