Smartphone, Laptop Prove Reliable and Accurate for Acute Ischemic Stroke Decision

Mobile devices proved both reliable and accurate for the clinical decision to administer IV thrombolysis in patients with acute stroke, according to an ahead-of-print article in the April issue of the American Journal of Roentgenology (AJR).

To assess reliability and accuracy of IV thrombolysis recommendations made after interpretation of head CT images of patients with acute stroke symptoms displayed on smartphone or laptop reading systems - compared with those made after interpretation of images displayed on a medical workstation monitor - Antonio J. Salazar at the University of Los Andes in Bogotá, Columbia utilized a factorial design with 188 patients, four radiologists, and three reading systems to produce 2256 interpretations.

To evaluate reliability, Salazar and colleagues calculated the intraobserver and interobserver agreements using the intraclass correlation coefficient (ICC) and five interpretation variables: hemorrhagic lesions, intraaxial neoplasm, stroke dating (acute, subacute, chronic), hyperdense arteries, and infarct size assessment. Accuracy equivalence tests were also performed for the IV thrombolysis recommendation; for this variable, sensitivity, specificity, and ROC curves were evaluated.

Good or very good intraobserver agreements were observed for all the variables. Specifically, for those variables required to establish contraindications for IV thrombolysis, the agreements were ranked as very good. "This finding is important," wrote Salazar et al., "because it reflects the good performance of mobile devices to evaluate the most significant imaging variables for clinical decisions."

For IV thrombolysis recommendation, the main subject of this evaluation, the interobserver agreements for the three reading systems were ranked as very good (ICC > 0.88). Similarly, very good intraobserver agreements were observed for all comparisons (ICC > 0.84). The AUC values (0.83-0.84) and sensitivities (0.94-0.95) for IV thrombolysis recommendation were equivalent among all the reading systems at a 5% equivalent threshold.

A unique assessment of imaging-based recommendations for the administration of IV recombinant tissue plasminogen activator based on unenhanced brain CT scans, Salazar also noted: "These results constitute a strong foundation for the development of mobile-based telestroke services because they increase neuroradiologist availability and the possibility of using reperfusion therapies in resource-limited countries."

Antonio J Salazar, Nicolás Useche, Sonia Bermúdez, Aníbal J Morillo, Oscar Tórres, Manuel F Granja, Natalia Rueda, Brenda Ropero.
Accuracy and Reliability of the Recommendation for IV Thrombolysis in Acute Ischemic Stroke Based on Interpretation of Head CT on a Smartphone or a Laptop
American Journal of Roentgenology, 2020. doi: 10.2214/AJR.19.21896.

Most Popular Now

AI-Pathway Companion Prostate Cancer fro…

AI-Pathway Companion Prostate Cancer(2), a digital companion from Siemens Healthineers to support clinical decision-making, has recently received the CE mark for use in the clinical pathway of prostate cancer, the...

Philips Launches HealthSuite System of E…

Royal Philips (NYSE: PHG, AEX: PHIA), a global leader in health technology, today announced the HealthSuite System of Engagement, an integrated, modular set of standards-based capabilities that support the development...

AI may Help Spot Newborns at Risk for Mo…

An artificial intelligence (AI) device that has been fast-tracked for approval by the Food and Drug Administration may help identify newborns at risk for aggressive posterior retinopathy of prematurity (AP-ROP)...

Boehringer Ingelheim Launches Patient-Ce…

Boehringer Ingelheim and Carebox Healthcare Solutions announced the recent launch of MyStudyWindow, a digital platform empowering patients, families, caregivers, and doctors to learn about Boehringer Ingelheim's studies by offering information...

Best of Breed: Start with Data in Open P…

Better is attending this year's Digital Health Rewired conference and exhibition at Olympia London alongside Taunton and Somerset NHS Foundation Trust, which is using its open platform to develop an...

Highland Marketing is Sponsoring the Caf…

Highland Marketing will be returning to Digital Health Rewired this year, where it will be sponsoring the café that has been created with an expanded exhibition area. Digital Health Rewired launched...

Siemens Healthineers Introduces Teamplay…

Siemens Healthineers announces market introduction of the teamplay digital health platform. With the teamplay digital health platform Siemens Healthineers paves the way for healthcare providers' digital transformation - facilitating easy...

International Scientific Symposium DigiH…

13 November 2020, Pfarrkirchen, Germany DigiHealthDay @DIT-ECRI is going to be a daylong action-packed event targeting primarily academia - from established researchers, to young scientists and students. Following the theme "How...

Digital Heart Model will Help Predict Fu…

In recent times, researchers have increasing found that the power of computers and artificial intelligence is enabling more accurate diagnosis of a patient's current heart health and can provide an...